下面是老外用stl编写的报警程序看不懂,请解释

郑志武 发布于2012-12-27 17:49 139 0 标签:

a"db61".c08177st1.jump

jcnp1

callfb2,db2
db_number:=2
op_selection:="db81".st1_op_selection
start_welding:="db81".step2_0
seconde:=m255.5
ten_of_seconde:=m255.0
tank_detection:="st1pipeplacedright2"
in_step_mode:="db81".st1_in_step_mode
step_mod_forw_autorisat:="db81".st1_step_mod_forw
acknowledge_step:=m90.3//db61.dbx5.0
waiting_step:=m90.4//db61.dbx5.1
rev_heat_carr_init_step:="db81".step0_5
rev_gripper_init_step:="db81".step0_3
with_auto_loading:=false//db61.dbx200.1
endautoloadclosgrippstep:="db61".c08177st1.endautoloadclosgrippstep
gripper_matching_timer:=t152
gripper_heating_timer:=t153
fusion_timer:=t154
cooling_timer:=t155
heating_elem_match_timer:=t156
heating_elem_heat_timer:=t157
synchro_gripp_heat_elem:=t158
open_time_timer:=t159
power_on:="st1poweroff(button)"
reset_station_operation:="db61".c08177_st1.reset_station_operation
auto_load_in_progress:="db61".c08177st1.auto_load_in_progress
default_acknowledge:="db61".c08177_st1.default_acknowledge
part_detection:="st1rovpresent"
step_mode_forward:="db81".st1_step_adv
step_mode_reverse:="db81".st1_step_ret
open_gripper_pb:=false
heat_grip_carr_forward:="st1transferheaterwp"
heat_grip_carr_revers:="st1transferheaterpp"
heating_gripper_flag:="st1gripperhp"
heating_heat_elem_flag:="st1mobilehotplatehp"
cooling_gripper_flag:="st1gripperwp"
gripper_reversed:="st1gripperpp"
heat_elem_reversed:="st1mobilehotplatepp"
gripper_opened:="st1gripperopen"
fixed_heat_elem_temp:="db61".temp_detect_st1f
mobil_heat_elem_temp:="db61".temp_detect_st1m
gripper_pressure_input:="db61".c08177st1.gripper_pressure_inputc
gripper_counter_press:="db61".c08177st1.gripper_counter_pressc
heat_elem_pressure_input:="db61".c08177st1.heat_elem_pressure_inpuc
heat_elem_count_press:="db61".c08177st1.heat_elem_count_pressc
rev_gripp_init_ord_press:="db61".c08177st1.rev_gripp_init_ord_press
fwd_gripp_init_ord_press:="db61".c08177st1.fwd_gripp_init_ord_press
rev_heat_init_ord_press:="db61".c08177st1.rev_heat_init_ord_press
fwd_heat_init_ord_press:="db61".c08177st1.fwd_heat_init_ord_press
rev_gripp_ord_low_press:="db61".c08177st1.rev_gripp_ord_low_press

佳答案

"db61".c08177st1.jump变量为1,执行fb2调用,下面是fb2接口参数赋值;"db61".c08177st1.jump变量为0,则跳转到p1标签处执行;要看懂fb2,需要打开fb2并对应接口参数看fb2的语句

若有收获,就点个赞吧!